PHOTOSTABILITY CHAMBER
Compact and functional chamber in conformity with ANVISA rules GUIDE ICH Q1B (option 2, UV radiation and fluorescent day-light lamp).
Product description
• Single chamber
• Test experience and measurement at the same exposition time
• When test is over the lamps go out and the equipment maintains temperature until the user arrives
• No complex controllers such as luxmeters and radiometers that need constant calibration
• The luminosity efficiency values can confirmed by chemical test (quinine chemical actinometric system), validated test by United States Pharmacopeia (USP, pharmacopeia forum 24m(3) : 6334, 1998) which determinates limit test time (VIS + UVA). This chemical method can be easily done in all samples expositions.
Technical Characteristics
• Mirrors on the inside for better luminosity distribution and uniformity
• Air circulation to guarantee constant temperature on the sample exposition area
• Automated locking system to prevent door opening during test time
• Hourmeter for lamp change control – indicates when lamps are improper for use
• Economical lamp use, easy access and no filters needed
• Ecological refrigeration system, no CFC
• Thermal isolation with low temperature dissipation and magnetic door sealing
• Temperature control and reading through sensor PT100 with 0,1o resolution
• Software with digital programmable timer that allows a test expe- riment of 99:59 recurring hours
• Microprocessor-controlled temperature with digital Led 4 digits dis- play and 0, 1oC resolution.
• Visual alarm system settable for highest and lowest temperature and for temperature range.
Technical Specifications
Temperature range |
15°C to 60ºC |
Temperature control |
PID |
Sample exposition area |
1400 cm² |
Integrated illumination |
> 1,2 m lux.h |
UV | > 200w.h/m² |
Temperature control resolution |
± 0,1ºC |
Digital Indication |
LCD |
Temperature sensor |
PT 100 |
Retransmission output |
4 to 20 ma |
Refrigeration system |
Hermetic compressor |
Refrigerating gas |
R134a |
Heating system |
Stainless steel tubular resistance |
Protection grade |
IP 20 |
Electrical specs |
110V or 220V 50Hz/60Hz |
INCLUDED ACCESSORIES AND COMPONENTS
• Side calibration door, 37 mm diameter • Operational manual • RBC Calibration Certificate, for temperature controller • Connection for Data Logger (4 to 20mA) |
OPTIONAL
• IQ, OQ e QD protocols
Photostability Chamber 424-CF Information
MODEL | INTERIOR | EXTERIOR | ||||
WIDTH mm | DEPTH mm | HEIGHT mm | WIDTH mm | DEPTH mm | HEIGHT mm | |
424-CF | 620 | 250 | 110 | 740 | 585 | 970 |
MODEL | WEIGHT Kg | ELETRICAL SPECS W |
424-CF | 51 | 600 |